Enhance 3-phase power efficiency with the JKW1B Series, a cutting-edge reactive power compensation controller designed for 3-phase low voltage systems (380V). This multifunctional power instrument integrates total harmonic distortion (THD) analysis, three-phase imbalance correction, and automatic power factor correction to optimize power quality and minimize energy losses. Engineered for smart grid compatibility, it offers 2-15th harmonic filtering, real-time power quality monitoring, and intelligent load balancing to stabilize 3-phase electrical power distribution. Ideal for industrial and commercial facilities, this power quality meter ensures low operational loss while managing 3-phase energy consumption and 3 phases of power dynamics. Compatible with power quality equipment, it addresses power quality harmonics and supports 3 phase current regulation for robust power of 3 phase reliability. Achieve seamless 3 phase 3 phase coordination and superior power quality compliance with the JKW1B Series—your all-in-one solution for advanced grid management.

 
 
 
 
 
 

    Main Product Datas

    Basic parameters

    Project Specification
    Rated Operation Voltage AC380±10%
    Rated Operation Current AC0~5A
    Rated Frequency 50Hz±5%
     Temperature -25℃~+55℃
    Rated Moisture The maximum relative temperature is 90%(at 20℃)
    Attitude ≤2000m
    Enviromental  There are no explosive or flammable hazardous medium, no corrosive gas to metals,
    and no conductive dust that damages electrical insulation.

    Control parameters

    Project Specification
    Output Static state
    Singal Frequency 50/60Hz
    Sensitivity 100mA
    Loop 1-12 Loop
    Method of  Method Co-compensation
    Target COSΦ preset 0.70~1.00; Step size 0.01; Factory preset 0.95
    Switching delay 1~250s
    Overvoltage protection Situations 380-500/230-260V; Step size 1V; Return difference 6V
    Undervoltage protection Level 340V/180V; Return difference 6V
    CT changes 50/5A-4000/5A; Step size 1
    Capacitive Capacity 0-125Kvar, factory preset 5Kvar for each branch
    Rated Contact  380V * 5A/220V * 7A Per branch

    Measurement Accuracy

    Project Specification
    Voltage ±1.0%
    Current ±1.0%
    Factor of Power  ±1.0%
    Reactive Power ±2.0%

    Adjustable range and factory setting values of control parameters

    Parameter code Meaning Setting Adjustable range
    PA-1 COS preset Hysteresis 0.95 Lag 0.8-100
    PA-2 Delay preset 30s 1-250s
    PA-3 Overvoltage preset 430V 230-260V/380-500V
    PA-4 Circuit preset 1-12 1-12 Circuits
    PA-4* CT Ratio preset Actual configuration 50~4000
    C-01 1st Circuit capacitor preset Actual configuration 0-150Kvar
    C-12 12th Circuit capacitor preset Actual configuration 0~150Kvar
    PA-1 Cut preset 1.00 0.70-0.70

     Introduction of JKW1B Series Reactive Power Automatic Compensation Controller 

    The JKW1B Series is a state-of-the-art reactive power compensation controller engineered to optimize 3-phase electrical power systems operating at 3-phase low voltage (380V). Designed for industrial and commercial applications, this multifunctional power instrument combines automatic power factor correction, total harmonic distortion (THD) analysis, and three-phase imbalance correction to ensure superior power quality and energy efficiency. By addressing power quality harmonics and implementing 2-15th harmonic filtering, it mitigates grid instability caused by nonlinear loads, reducing operational losses and extending equipment lifespan. Its real-time power quality monitoring capability provides granular insights into voltage fluctuations, 3-phase current imbalances, and reactive energy compensation needs, enabling proactive adjustments for smart grid compatibility. With intelligent load balancing, the controller dynamically redistributes loads across 3 phases of power, minimizing reactive power in power systems and enhancing the power of 3 phase reliability. Ideal for facilities prioritizing low loss operations, the JKW1B Series supports reactive electricity management and reactive voltage stabilization, ensuring compliance with global energy standards. As a critical component of power quality equipment, it integrates seamlessly with 3 phase 3 phaseinfrastructures, delivering robust performance for 3 phase energy optimization and global power energy sustainability.
    Advanced Features for Modern Grid Demands
    Built to excel in complex electrical environments, the JKW1B Series excels in reactive power compensators technology, offering precise function of reactive power regulation to stabilize three-phase power networks. Its multifunctional power meter functionality extends beyond basic measurements, providing detailed analytics on power quality harmonics, reactive power in electrical systems, and 3-phase electrical power consumption patterns. The device’s smart grid compatibility ensures adaptability to evolving grid demands, while real-time power quality monitoring empowers users to detect anomalies like voltage sags, swells, or harmonic distortions instantly. For facilities operating at low voltage 380V, the controller’s 2-15th harmonic filteringcapability neutralizes high-frequency disturbances, safeguarding sensitive equipment from damage. The integrated automatic power factor correction system dynamically adjusts capacitive and inductive loads, optimizing reactive power compensation to reduce penalties from utility providers. Additionally, its intelligent load balancing algorithm ensures even distribution of 3 phase current, addressing three-phase imbalance correction to prevent overheating and energy waste. Compatible with renewable energy integrations and IoT-enabled power quality equipment, the JKW1B Series is a future-proof solution for industries aiming to enhance power quality meter accuracy and achieve global power energy efficiency goals. By harmonizing reactive energy compensation with 3 phase 3 phase coordination, this controller sets a new benchmark for the reactive power management in modern electrical systems.

     

    JKW1B Series Reactive Power Automatic Compensation Controller Thd Three-Phase Reactive 2-15 Harmonic Multifunctional Energy Power Meter 380V

    Functions of JKW1B Series Reactive Power Automatic Compensation Controller 

     

    • Low-loss operation ensures optimal three-phase energy efficiency in three-phase low-voltage (380V) systems, minimizing reactive power wasted in the grid.
    • Advanced reactive power compensation controller with total harmonic distortion (THD) analysis to suppress power quality harmonics and stabilize three-phase power distribution.
    • Automatic power factor correction dynamically adjusts reactive energy compensation, optimizing power quality and reducing penalties for grid operators.
    • Integrated 2-15th harmonic filtering eliminates high-frequency interference and protects power quality equipment from reactive voltage fluctuations.
    • Multifunctional power instrument provides real-time power quality monitoring of three-phase current, voltage unbalance, and reactive power in three-phase power systems.
    • Smart grid compatibility enables intelligent load balancing of three-phase power and solves the problem of three-phase imbalance correction, thereby enhancing the reliability of three-phase power.
    • Robust reactive power compensators solve reactive power issues in power systems and ensure seamless functionality of reactive power regulation in compliance with global power energy standards.
    • Designed for three-phase three-phase coordination, this power quality meter supports reactive power management and reactive power compensation in industrial and commercial power grids.

    JKW1B Series Reactive Power Automatic Compensation Controller Thd Three-Phase Reactive 2-15 Harmonic Multifunctional Energy Power Meter 380V

     

     Working Principle of JKW1B Series Reactive Power Automatic Compensation Controller 

    Reactive power compensation controller and three-phase balancing module
    The reactive power compensation controller optimizes the three-phase power system by dynamically adjusting reactive power compensation to offset the inefficient operation of the three-phase low-voltage (380V) power grid. It uses real-time data from multi-function power meters to detect reactive power in the power system and trigger capacitor banks or reactors to eliminate inductive/capacitive imbalances, thereby achieving automatic power factor correction. At the same time, the three-phase unbalance correction module monitors the three-phase current differences and redistributes the load between the three-phase power sources, thereby stabilizing the reactive voltage and minimizing the waste of low-loss electrical energy. This dual-action mechanism improves power quality by maintaining balanced three-phase power flow, reducing grid stress, and meeting global power efficiency standards.
    Harmonic filtering and THD analysis unit
    Integrated 2-15th harmonic filtering technology is designed to reduce power quality harmonics generated by non-linear loads such as frequency converters or inverters in three-phase systems. The device uses passive/active filters to suppress harmonic distortion up to the 15th order, while a total harmonic distortion (THD) analysis module continuously scans the voltage and current waveforms to quantify harmonic pollution. Data from power quality meters is input into an algorithm that adjusts the intensity of the filter in real time to ensure compliance with IEEE-519 standards. By eliminating high-frequency noise and stabilizing reactive currents, the device prevents power quality equipment from overheating and extends the service life of three-phase power infrastructure. Its real-time power quality monitoring capabilities can also alert operators to emerging harmonic risks, allowing proactive mitigation.
    Smart grid interface and load balancing system
    JKW1B's smart grid-compatible module enables seamless integration with modern energy networks through IoT-based real-time power quality monitoring and adaptive intelligent load balancing. The system analyzes three-phase energy consumption patterns and redistributes loads on three-phase power lines to prevent any single-phase overload. By optimizing reactive power distribution and aligning it with the reactive power demand function, the module minimizes reactive power in the grid and improves the reliability of three-phase power supply. The module also supports two-way communication with grid operators, allowing dynamic adjustment of reactive power compensators based on demand response signals. For low-voltage 380V applications, it ensures stable operation even at peak loads, and its reactive compensation algorithm complies with the global power energy sustainability framework, making it ideal for hybrid renewable energy grid systems.

     

    JKW1B Series Reactive Power Automatic Compensation Controller Thd Three-Phase Reactive 2-15 Harmonic Multifunctional Energy Power Meter 380V

     

    Wiring Method for JKW1B Series Reactive Power Automatic Compensation Controller 

    Voltage input
    The controller has an automatic phase sequence judgment function, but the input voltage should be as consistent as possible with the input current, that is, the phase number and phase sequence must be consistent. At this time, either the BC line voltage or the A phase voltage can be used as a signal; the wiring method should be adjusted accordingly.

    Current input

    The current is taken from the A line current. The standard rated input current is 5A. When it is greater than 5A, an external current transformer (CT) is required.
    Although the controller has an automatic phase sequence judgment function, the inputs should have the same nature in terms of phase and phase sequence number.
    If other instruments are connected to the CT, the wiring should be connected in series.
    Before removing the current input wiring of the product, please disconnect the primary circuit of the CT or short-circuit the secondary circuit.

    CT Connection

    In order to facilitate disassembly and assembly, terminal blocks should be used instead of direct connection to CT.

    Communication wiring

    The network power meter is equipped with an asynchronous half-duplex RS485 communication interface for data transmission on a communication line that follows the MODBUS-RTU protocol. A maximum of 128 network power meters can be connected to one line at the same time, and each network power meter has its communication address (Addr) set.
    It is recommended to use shielded twisted pair cables for communication connection, with a wire diameter of not less than 0.5 mm. The common terminal can be omitted, or if the common terminal is grounded, a "single-ended single-point grounding" system must be used. Connect a terminal matching resistor of 120 Ω to 1 kΩ between the A and B terminals of the terminal instrument. When wiring, the communication line should be kept away from high-current cables or other strong electromagnetic field environments.
    In order to protect the safety of the communication interface and the controller itself, the switch input interface and temperature interface must be isolated from other external active devices, because RS485 is not isolated from these interfaces.

    Number of main switch outputs
    Active output is the switching control of compensation capacitors, which is used to synchronize different customer instructions, and the number of channels is 6, 8, 10 or 12. Capacitor switching modes include first-in-first-out switching, sequential switching, manual switching, and communication switching.

    This mode is called sequential switching and is suitable for situations where different groups of compensation capacitors have different capacities. Each group of compensation capacitors must be wired in descending order of capacity. The capacitor with the largest capacity should be connected to K1, and the capacitor with the smallest capacity should be connected to K2.
    FIFO switching is applicable to compensation capacitor groups of the same capacity. In this case, the FIFO method can ensure that the operating time loss of each group of capacitors is equal.
    Mainly used in the debugging stage, manual switching is used to evaluate the wiring and compensation effects. In the measurement display mode, the capacitance value can be input and output by the left and right keys.
    Communication switching is to remotely control the capacitor through the instructions issued by the controller. At this time, the controller abandons the control function but retains the protection part. Other devices write relevant content into the controller through communication to realize the switching of the capacitor.

    JKW1B Series Reactive Power Automatic Compensation Controller Thd Three-Phase Reactive 2-15 Harmonic Multifunctional Energy Power Meter 380V

     

    Product Size

    JKW1B Series Reactive Power Automatic Compensation Controller Thd Three-Phase Reactive 2-15 Harmonic Multifunctional Energy Power Meter 380V

    Model Hole opening size
    JKW1B 140×102mm

    Applications of JKW1B Series Reactive Power Automatic Compensation Controller 

    Applications of JKW1B Series Reactive Power Automatic Compensation Controller 

    Industrial Manufacturing Facilities

    The JKW1B series excels in demanding industrial environments where three-phase power systems face challenges such as power quality harmonics, three-phase unbalance correction, and fluctuating reactive power in the power system. Its reactive power compensation controller dynamically manages reactive power compensation, ensuring stable operation of heavy machinery at three-phase low voltage (380V) while minimizing low-loss power waste. Integrated total harmonic distortion (THD) analysis and 2-15th harmonic filtering eliminate harmonics generated by inverters and non-linear loads, protecting power quality equipment from damage. With automatic power factor correction, the controller optimizes three-phase energy efficiency, reduces fines from power companies, and stabilizes reactive voltage fluctuations. Real-time power quality monitoring through its multi-function power meter provides actionable insights into three-phase current imbalance and reactive power dynamics, enabling proactive maintenance. Ideal for plants that focus on power quality and global power standards, the JKW1B ensures seamless coordination between the three phases, thereby increasing productivity and reducing downtime.

    Applications of JKW1B Series Reactive Power Automatic Compensation Controller 

    Smart Buildings & Data Centers

    In mission-critical environments such as data centers and smart buildings, the JKW1B series ensures reliable three-phase power distribution through intelligent load balancing and reactive power compensators. Its smart grid compatibility enables adaptive reactive power management, which is critical to maintaining the normal operation of three-phase low-voltage (380V) systems that power servers, HVAC, and lighting. The power quality meter function detects power quality harmonics and reactive power in the circuit, while the real-time power quality monitoring function alerts operators when the voltage sags or swells. 2-15th harmonic filtering mitigates interference from IT equipment, and automatic power factor correction optimizes three-phase energy consumption in line with sustainable development goals. By addressing three-phase unbalanced correction and stabilizing reactive voltage, the controller protects sensitive electronic equipment and reduces cooling costs. It is designed for three-phase reliability power supply and supports reactive power compensation in dynamic load environments, ensuring compliance with global power efficiency certifications for green buildings.

     

    Applications of JKW1B Series Reactive Power Automatic Compensation Controller 

    Renewable Energy Systems (Solar/Wind Farms)

    The JKW1B series is essential in renewable energy systems because intermittent power generation from solar arrays or wind turbines introduces reactive power, causing power system instability and harmonic distortion. Its reactive power compensation technology stabilizes the three-phase power flow connected to the grid, ensuring that three-phase power is smoothly integrated into the global power network. The controller's 2-15th harmonic filtering function solves harmonic problems caused by inverters, while the total harmonic distortion (THD) analysis function ensures compliance with grid regulations. The automatic power factor correction function adjusts reactive power compensation in real time to offset voltage fluctuations caused by fluctuations in power generation. Smart grid compatibility enables intelligent load balancing of three-phase power, optimizes energy scheduling, and minimizes losses during peak cycles. With real-time power quality monitoring, operators can view three-phase current imbalance and reactive voltage curves to ensure stable operation at 380V low voltage. By enhancing reactive power regulation capabilities and three-phase power reliability, the JKW1B supports scalable and resilient renewable energy infrastructure in line with global power energy sustainability goals.

    Storage Workshop

    Intelligent Cylindrical Capacitor Storage Workshop     Intelligent Cylindrical Capacitor Storage Workshop     Intelligent Cylindrical Capacitor Storage Workshop

    Production workshop

    Digital Cylindrical Capacitor Production Workshop   Digital Cylindrical Capacitor Production Workshop    Digital Cylindrical Capacitor Production Workshop

    Workshop Vedio

    Baoyu Holdings Limited 

    Baoyu Holding Co., Ltd. was founded in 2015 and is located in Wenzhou City, Zhejiang Province. The location is excellent and the transportation is convenient. We have very rich industry experience and is a trusted supplier. The company has advanced production equipment and skilled front-line employees. Our company is mainly engaged in the production and sales of power quality products,such as active power filters, static var generators, intelligent capacitors, power capacitors, reactive power compensators, composite switches, capacitor contactors, thyristor switches, reactors. Our company knows that the development of the company depends on the innovation and quality of the products. Therefore, our products have strict quality control from the procurement of raw materials to the sale of finished products. The company has established a quality management system that meets the requirements of the international quality management system. The company continuously releases the original innovations according to the market and customer needs, and always maintains the novelty and innovation of the products. The company wants the customer's thoughts and urgency. Solving problems for customers and meeting customer needs is our eternal pursuit! Our company's products are sold worldwide. The company has won the unanimous recognition of consumers with satisfactory product quality and perfect after-sales service. We have a professional R & D team. We can accept O E M and O D M.We sincerely welcome friends from all over the world to visit our company and cooperate with us on the basis of long-term mutual benefits. We are looking forward to receiving your enquiry soon. 

    Our storage facility utilizes precision climate control, automated 3D warehousing (which increases capacity by 200%), and integrated safety systems (including fire suppression, anti-static protocols, and monthly audits) to maintain zero oxidation and ensure product integrity. In addition, our cleanroom manufacturing facility features a combination of natural and LED lighting, optimized workflows, and cross-trained technicians to enhance efficiency. Automated quality control systems and ISO-certified processes ensure compliance with dimensional and electrical standards, while AI-driven analytics and stringent protocols help achieve near-zero defects. By integrating advanced automation, tailored solutions, and steadfast reliability, Baoyu provides durable, mission-critical power systems, reinforcing our status as the preferred global partner for industries that require precision and innovation.

    Business license

    Baoyu Holding Co., Ltd

    High-tech enterprise certificate

    Baoyu Holding Co., Ltd      

    ISO management system certification

                                                                                Chinese APF manufacturersChinese APF manufacturersBaoyu Holding Co., Ltd

    Corporate honors

    Chinese APF manufacturers

    Chinese APF manufacturers
        

    Product certification certificate

    Chinese APF manufacturers

    Product testing report

    Chinese APF manufacturers

     

    Company patent certificate

    Chinese APF manufacturers

    Well-known domestic partners

    Chinese APF manufacturers

    Leave Your Message