Power Capacitors
- BY71 Series Cylindrical Capacitor
- BSMJ Series Self-healing Low Voltage Shunt Capacitors
- BY86 Series Controlled Intelligent Capacitor
- BYKXG/F Series Anti-harmonic Intelligent Capacitor
- BY81 Series Intelligent Capacitor
- BY82J Series Anti-harmonic Intelligent Capacitor
- BY89 Series Intelligent Capacitor
- Intelligent Controller Series
- Reactor
- Intelligent Switch Series
- Alternating Current Contactor
- Multifunctional power instruments
- Circuit Breaker
- APF/SVG/SPC Cabinet & Module Series
BYM6 Series Photovoltaic High-Voltage Molded Case Circuit Breaker AC 1140V
Parameter Information of BYM6 New Energy Circuit Breaker
| Model | BYM6 New energy circuit breaker |
| Production level | IP20 |
| Extreme number | 3P |
| Rated current In (A) | 800A |
| Rated ultimate short-circuit breaking capacity Lcu (kA) O-CO : AC 800V | 36.5kA |
| Rated impulse withstand voltage Uimp (kV) | 12 |
| Rated working voltage Ue (V) | Up to 1140V |
| Total breaking time (without additional delay) (ms) | 12~28 |
| Closure time (ms) | ≤60 |
| Working Voltage (V) | Up to 1140V |
| Machine lifespan (times) | 20000 |
| Temperature protection | All series are equipped with temperature protection |
BYM6 New Energy Circuit Breaker Product Introduction
Baoyu Electric has developed the BYM6 Series High-Voltage Molded Case Circuit Breakers after years ofdedicated research into domestic and international new energy system operations and customer needs. These circuibreakers are desianed for high-voltage applications, with a rated voltage up to AC 1140V and a current rating up to800A.Under an Ac 800V voltage, the BYM6 series circuit breakers offer a breaking capacity of up to 36.5kA, ensuringreliable short-circuit protection for the system.Standards:lEC60947-1GB/T 14048.1:General ruleslEC 60947-2 GB/T 14048.1:Circuit breakers
High Voltage Compatibility: Rated for AC 1140V and compatible with 1140V DC/AC systems, the BYM6 Series supports modern high-voltage solar arrays, reducing energy loss and enhancing grid-tie efficiency.
Robust Protection Mechanisms: Equipped with overload long-delay protection and short-circuit instantaneous protection, it safeguards PV inverters, transformers, and distribution lines from damage, ensuring compliance with stringent safety standards.
High Breaking Capacity: Engineered for ultra-high breaking capacity (up to 36.5kA), this MCCB minimizes downtime by isolating faults swiftly, even in demanding industrial environments.
Compact & Durable Design: Featuring a shake-proof, compact structure and corrosion-resistant housing, it excels in harsh conditions, from offshore solar farms to desert installations.

BYM6 New Energy Circuit Breaker Product Features
The BYM6 Series operates as a critical safeguard in high-voltage AC 1140V photovoltaic systems, designed to interrupt fault currents during overloads, short circuits, or abnormal voltage conditions. Its core functionality revolves around:
Thermal-Magnetic Trip Mechanism:Thermal Protection,A bimetal strip responds to prolonged overcurrents (e.g., caused by equipment overload or insulation degradation). As temperatures rise, the strip bends, triggering a mechanical release to disconnect the circuit.
Magnetic Protection: A solenoid coil detects sudden current spikes (short circuits). When the current exceeds the predefined threshold (e.g., 10x the rated current), the magnetic force instantly trips the breaker, isolating the fault within milliseconds to prevent equipment damage or fire hazards.
Arc-Quenching Technology:The breaker’s molded case design incorporates arc chutes and splitter plates to rapidly cool and extinguish arcs generated during interruption. This ensures minimal downtime and enhances system longevity, even under extreme fault conditions.
PV-Specific Adaptations:High Voltage Compatibility: Optimized for AC 1140V systems, it supports the increasing voltage demands of modern solar farms and grid-tied inverters, reducing energy loss and improving transmission efficiency.
Environmental Resilience: Engineered to withstand harsh outdoor conditions, including temperature fluctuations (-25°C to 70°C) and UV exposure, ensuring reliable performance in solar installations

Product size information


Choosing us means choosing quality

The heart of the circuit breaker holds the contact system. It stops the flow when there is too much power or short circuits. This keeps both the gear & folks safe. The design must take on full-bore flow. It should act fast if there's too much flow. If not, it may get too hot or break. The parts & build of the contact points need to be top notch. They should pass the flow well & be strong. This cuts flow block & makes them last long. The gears & wires in the breaker must sync well. They must cut the link well when there are faults. This cuts the risk of fires & gear break. It keeps the power system safe.

The arc-killing room is key too. It kills the arc & cuts off the flow. When the flow stops, an arc shows up at the touch points. The room stops the arc from getting big by keeping each end apart. It uses special stuff to cool the arc fast & stop the heat. This keeps the gear safe. It also stops stray flow, which keeps folks safe. By making the room well, the breaker works better & more safe. This ensures safe work in all states.

High flow stuff is key in all gear. This stops shocks & makes the power set-up firm. These stuff show tiny hold-back when flow goes through. This cuts the push-back from the flow. Big push-back in high stress can make the gear shake or break. Using good stuff keeps the flow fine & loses less flow. So, we get good flow & quickly guide faults along a safe way. This drops shock risk. By using good stuff in wires, the power set-up stays firm. This makes gear work well & safe when there's a big load. This ups how well gear works & keeps folks safe.
Application Scenarios of BYM6 New Energy Circuit Breaker



Charging system Photovoltaic industry Industry
Storage Workshop

Production workshop

Workshop Vedio
Why Choose Baoyu Holding Co., Ltd.?
1. Precision & Reliability: Our products deliver high-accuracy power quality monitoring and real-time harmonic suppression, ensuring stable voltage, reduced energy loss, and compliance with international standards like IEEE 519 and IEC 61000. Ideal for industries sensitive to voltage fluctuations, such as semiconductor manufacturing, data centers, and automotive plants.
2. Smart Grid Integration: Leveraging IoT , our systems enable remote monitoring, predictive maintenance, and automated power optimization, aligning with the global shift toward smart grids and energy-efficient infrastructure.
3. Sustainability Focus: As renewable energy adoption surges, our solutions mitigate challenges from solar/wind integration, addressing voltage sags, frequency variations, and reactive power imbalances to enhance grid resilience.
Key Applications
Industrial Facilities: Minimize downtime and equipment damage caused by harmonics and voltage instability in mining, steel, and chemical plants.
Commercial Buildings: Ensure uninterrupted operations for hospitals, airports, and shopping malls with dynamic reactive power compensation.
Renewable Energy: Optimize grid integration for solar/wind farms, reducing harmonic distortion and improving power factor.
Innovation & Partnerships
Collaborating with top-tier institutions like Shanghai University, we hold 20+ patents and continuously refine our R&D to lead in energy-saving technologies and customized solutions.
Keywords: Smart Power Quality Solutions, Active Harmonic Filter, Static Var Compensator, Reactive Power Compensation, Voltage Stabilization, Energy Efficiency Solutions, IoT-based Power Management, Renewable Energy Integration Devices.Explore how BaoYu’s full-controlled intelligent systems can transform your energy infrastructure. Contact us today for a free consultation and unlock seamless, sustainable power performance.
Business license

High-tech enterprise certificate
ISO management system certification



Corporate honors


Product certification certificate

Product testing report

Company patent certificate

Well-known domestic partners